The Gemini 501A Smoke Detector Analyzer
Technical Data
Tests all detectors
Portable, fast, easy to use
UL
Listed
Harmless
Meets all NFPA
72-E
Reaches detectors 30 ft high
requirements
NFPA 72
The National Fire Protection Association (NFPA) code 72
requires periodic inspection and testing of smoke detectors.The required test
includes a calibrated sensitivity test to assure that each detector is within
its listed sensitivity range and each
detector would initiate an alarm when exposed to smoke.Local codes and other
accrediting associations require similar sensitivity testing of smoke detectors.
The Gemini 501 Tester
The Gemini 501A Smoke Detector Tester is a calibrated test
instrument. It produces an adjustable, stable smoke from a special FDA grade
natural mineral oil. The smoke is created by a nebulizer, not by heat or
flame.The smoke particle sizes and size distribution generated by the Gemini
501A resemble the smoke from the UL-268 Standard Smoke Box. Because of the
small particle sizes, low concentration, and short exposure time, this smoke is
not harmful to the detectors or operator. The Gemini 501 A is approved by
leading smoke detector manufactures.
UL Listed
The Gemini 501 A Smoke Detector Tester is UL listed as an
approved sensitivity test instrument for all smoke detectors. Prior to its
approval, Underwriters Laboratories evaluated to its satisfaction the
correlation of test results for detector sensitivity between the Gemini 501 and
the UL-268 Standard Smoke Box.
Smoke Detectors
All types of smoke detectors are designed to alarm when
exposed to low concentrations of smoke to assure early detection of fire. The
concentration of smoke is measured in per cent of obscuration per foot (%/ ft
obs), a standard used by Underwriters Laboratories.
After installation, the sensitivity of smoke detectors can
shift due to dirt, adverse conditions, or aging. If the smoke detectors lose
their sensitivity, the advantage of early fire detection is lost. In some cases,
they may not function at any concentration. If too sensitive, the detectors may
cause false alarms.
Portable, easy to use
The Gemini 501 A Smoke Detector Tester was specifically
designed for testing installed smoke detectors by service personnel. It is
portable and is easy to use.
The Gemini 501A tests all smoke detectors: all types, all
brands; no extra modules, meters or connectors. One easy to learn procedure
tests all detectors. It comes with extension wands to test detectors on ceilings
up to 20 feet high. With optional wands, detectors on ceilings as high as 30
feet can be tested without a ladder or lift. Using readily available fittings,
the wand can be modified to test hard to reach detectors.
Principles of Operation
The Gemini 501A Smoke Detector Tester uses a nebulizer to
produce a spray of particles. An impactor removes the large particles, leaving
micro, smoke sized particles. The smoke resembles in size the smoke in the UL
268 Smoke Box. The built in compressor- vacuum pump supplies air pressure for
the nebulizer and an adjustable vacuum to remove excess concentration of smoke.
A blower supplies room air to dilute the smoke and transport it through the hose
and wands to the detector.
Test Procedure
After setting up of the Gemini 501A tester, it is adjusted
to produce the same per cent obscuration smoke as the listed rating of the
detector. The detector should alarm within 30 seconds. A second test may be
conducted to determine if the smoke detector sensitivity is within an acceptable
range.
This test is both a senstivity and a functional test. A
Gemini 501A sensitivity test adds a minimal amount of time to a standard smoke
detector cleaning and testing procedure.
Quality construction
Since 1982, the Geminis have been supplied to hospitals,
nuclear facilities and fire alarm service companies. Each Gemini is carefully
built using quality, rugged components assuring durability in the field. Prior
to shipment each Gemini 501A is thoroughly inspected, tested and individually
calibrated with a Mass Particle Monitor and Standard Reference Detectors. The
instrument output is presented as both mass concentration in mg/m3
and smoke obscuration in %/ft.
For detailed specifications see:
Gemini 501A brochure.pdf
For prices see:
Gemini Price List
|